On first installation, using a hand grease gun and the same type of grease, pump a few shots of lubricant into the bearing. If fittings or grease lines are used, these also should be filled with the same lubricant.
If possible, install the ELECTRO-LUBER MD TM directly on the bearing. All ELECTRO-LUBER MD TM units have ½” NPT threads. The units will come with a brass adapter (1/4” or 1/8” NPT outlet) specified at time of order. Each adapter comes with an o-ring, which must be installed with the adapter to prevent leakage. (steel adapters can be substituted for brass; stainless steel adapters available at a nominal extra charge.)
If the ELECTRO-LUBER MD TM is remotely mounted, the following applies:
It is important to
make sure you prime all piping and lube points prior to installing
the ELECTRO-LUBER MD TM.
For optimal performance, the MD unit works best with multi-grade lubricants. (a recommended list is available from ATS Electro-Lube) High temperature lubricants, with an NLGI 2 or higher rating, tend to harden at low temperatures, therefore, lower NLGI ratings are recommended. In low temperature applications use Lowtemp lubricants with NLGI 0 or 1 rating.
Each ELECTRO-LUBER MD TM is supplied with a weather proof switch cap with O-Ring which MUST be used in all cases as protection against weather and moisture.
To insure the success and reliability of your ELECTRO-LUBER MD TM installation, do not use in temperatures below 14 deg. F.(-10 deg. C.) or above 170 deg. Fahrenheit (76 deg. C.), or in an application requiring more than 200 psi. The Alkaline battery packs can be used up to 131°F (55°C), the Lithium battery packs can be used up to 170°F (76°C). The MD unit is designed to feed multiple points using progressive distribution blocks. (4, 6, & 8 port blocks available from ATS Electro-Lube).
The ELECTRO-LUBER MD TM is completely waterproof provided the switch cap is installed properly. It can be used underwater to depths of 60 feet (20 metres).
NOTE: DO NOT RUN THE ELECTRO-LUBER MD TM 2000 WITHOUT GREASE. THIS MAY DAMAGE THE UNIT AND THE WARRANTY WILL BE NULL AND VOID.
Starting Procedure
Referring to the proper model’s dispensing rate chart on page 3 or 4, select the dispensing time and amount of lubricant required. Then set the appropriate switch or switches to the setting which corresponds to the period of time it takes to empty the unit. This action activates the unit, and within 1 minute the first cycle will commence dispensing.
Selection of for Switch Settings
One stroke from a typical grease gun is equal to approximately one cubic centimetre (cc). To select the switch setting appropriate for your application look down the column for the desired output of lubricant, remembering that 1 cc is equal to approximately one stroke from a grease gun. The switch setting for your selection is shown in the right most columns labelled Switch1 to Switch7.
NOTE: Not
responsible for consequential damage beyond replacement of
ELECTRO-LUBER TM or refund of amount paid.
For
other settings or special applications,
Please contact: